Suchen Sie etwas anderes?
WAVENIS_ prefix parameters relate to MTX-Tunnel featured with a Coronis card for concentrator applications: it reads and controls remote sensors to MTXTerminals using an RF 868 MHz radio link.
The WAVENIS_ parameters are only to be used when MTX-Tunnel is operating on an MTX-IND platform with a Wavecard installed inside.
Please also read “LOGGER_” related parameters.
Table of Contents
WAVENIS_mac1, WAVENIS_mac2… WAVENIS_mac32
Description: This parameter allows the Coronis device’s MAC addresses to be read. MTX will periodically read the remote devices specified by their own MAC identification. You need to specify the repeaters if you are going to use them.
Possible values:
- AABBCCDDEEFF; XX; YY; ZZ
- AABBCCDDEEFF: MAC wavenis Coronis card
- XX; YY; ZZ: 1, 2, … 10 repeaters used
- Default value: None
Additional notes:
- Please use the technical support line at iotsupport@mtxm2m.com for further information.
WAVENIS_rep1, WAVENIS_rep2… WAVENIS_rep10
Description: Repeater MAC address is used in Wavenis communications. You can use up to 10 repeaters.
Possible values:
- AABBCCDDEEFF Wavenis MAC repeater address
- Default value: None
Additional notes:
- Please use the technical support line at iotsupport@mtxm2m.com for further information.
WAVENIS_period
Description: This parameter sets the time period in seconds. MTX-Tunnel reads the Coronis devices already configured in the WAVENIS_macXX parameter.
Possible values:
- 0… 2592000
- Default value: 0
Additional notes:
- Keep in mind that a single remote RF device reading can take from 2.5 seconds up to 10 seconds if repeaters are used. For example if MTX-Tunnel has to read 10 remote sensor RF cards, the device readings can take from 25 up to 100 seconds providing no error communication occurs. Please use this parameter in an appropriate way
- We recommend the minimum value of 30 seconds if only one Coronis card is used
- Readings are stored in MTX-Tunnel internal Logger memory. Read Logger_ parameters for more information.
- Please use the technical support line at iotsupport@mtxm2m.com for further information.
WAVENIS_retries
Description: The amount of times that you retry obtaining a reading in case of errors with MTX-Tunnel and its communication link to the remote Coronis card.
Possible values:
- 0,1,2,3
- Default value: 2
Additional notes:
- We recommend setting the value to 2. This means that 2 retries will be done in the event an error occurs on the 1st reading
- Please use the technical support line at iotsupport@mtxm2m.com for further information