Tunnel – Monitoring of 7 meters with pulse outputs via MQTT with alarm to detect the opening of the meter access door.
Scenario details: 7 counters with pulse output need to be monitored. Therefore, a modem with 7 pulse counter inputs is required. The accumulated pulses must be sent to a web platform via MQTT every 60 minutes The meters will be installed in manholes and register boxes which are locked. It is necessary to monitor the […]
Tunnel – Configuration parameters related to analog inputs: “ADC_”
Most MTX modems have one or more analog inputs (0-50V or 4-20mA). The ADC_ parameters allow you to configure the behavior of these analog inputs. For example, you can configure an analog input so that when it exceeds a level, it will send alarm SMS, or send an MQTT message, or make a voice call, […]
Tunnel – Digital I/O and relay configuration parameters: “GPIO_”
Most MTX modems have one or more digital inputs and outputs, and even relays. The GPIO_ parameters allow configuring the behavior of these inputs and outputs. For example, you can configure a digital input so that when it changes state, it will send alarm SMS, or send an MQTT message, or make a voice call, […]
Tunnel – AT Commands Batch Files
Inside the flash memory of the modem is a folder called “atscripts”. Within this folder batch files of AT commands can be incorporated to be executed on certain occasions or by using the command AT ^ MTXTUNNEL = file.For example, if a “miscommands.txt” file is found inside the “atscripts” folder with the content: AT^MTXTUNNEL=SETIO,0,1PAUSE 5 […]
I/O Description: MTX-IOT [4-S-P-N]
Description of I/O interfaces: DB15 expansion connection: 3 digital inputs (2 of them pulse counters), 2 digital outputs and 2 A/D conversors (0-50V in tension mode, 0-20mA in current mode) Serial interfaces: 1x RS232 (DB9), 1x RS232 (DB15) Relay: 1x internal relay 6A (220Vac). Accessible from terminal block MTX-Tunnel software uses these inputs/outputs as follows: […]
I/O Description: MTX-IOT [4-S-N-WC868]
Description of I/O interfaces: DB15 expansion connection: 3 digital inputs (2 of them pulse counters), 2 digital outputs and 2 A/D conversors (0-50V in tension mode, 0-20mA in current mode) Serial interfaces: 1x RS232 (DB9) or 1x RS485 (configurable with switches) Wavecard 868MHz: internal radio card, connected to secondary port MTX-Tunnel software uses these inputs/outputs […]
I/O Description: MTX-2G-T2 / MTX-3G-JAVA-T2 / MTX-4G-JAVA-T2
Description of I/O interfaces: Serial interfaces: 1x RS232 (DB9), 1x RS232 (secondary DB9) MTX-Tunnel software uses these inputs/outputs as follows: GPIO LOCATION PIN I/O FUNCTION @MODBUS GPIO3 Terminal block 3 Digital input SMS alarm/user/pulse counter 3/17-18 The column “GPIO” indicates the virtual GPIO corresponding to the GSM module inside the modem The column “Location” informs […]
I/O Description: MTX-2G-T / MTX-3G-JAVA-T / MTX-4G-JAVA-T / MTX-4G-JAVA-T-S
Description of I/O interfaces: Serial interfaces: 1x RS232 (DB9), 1x RS485 GPS: internal, only in MTX-3G-Java-T-G model MTX-Tunnel software uses these inputs/outputs as follows: GPIO LOCATION PIN I/O FUNCTION @MODBUS GPIO3 Terminal block 3 Digital input SMS alarm/user/pulse counter 3/17-18 The column “GPIO” indicates the virtual GPIO corresponding to the GSM module inside the […]
Titan – AN38: RS232, RS485 and USB serial port redirects
Scene Details MTX-Titan-Router has all the typical features of a 2G/3G/4G router and also has additional features that make it one of the routers with the most features on the market. This application note shows how to redirect the input data flow from a serial port (RS232/RS485/USB) of the Titan router to another of its […]
Titan – AN37: How to use MQTT-USB/RS232/RS485 gateways
Scene details MTX-Titan-Router has all the typical features of a 2G/3G/4G router and also has additional features that make it one of the routers with the most features on the market. One of the additional features is the ability to make up to 5 simultaneous IP gateways-RS232/RS485/USB. That is, with the Titan router you can […]